Comparison Chart Pi-UpTime UPS vs. Pi-UpTime UPS 2.0

This table compares the older version of Pi-UpTime UPS with the current version of Pi-UpTime-UPS 2.0

Pi-UpTime-UPS Pi-UpTime-UPS 2.0
Charge Current Max 1.0 A Max 1.2A
Battery Chemistry (battery not supplied) Li-Ion 18650 battery Li-Ion/Li-Polymer OR Lithium Phosphate, jumper selectable
Battery Holder On top, 2×18650 size On top, like previous version OR external via terminal block
Access to Vin, Vout, Battery No Yes, via terminal blocks, and in software via the on-board ADC
Input V Max 5.5V, via micro USB only Max 5.5V, via micro-USB (in) OR via terminal blocks (not included)
Output V 4.6V to 5.1V Vin, when present is passed through. UPS output regulated to 5V out (±2%). No irritating “bolts” on Raspbian
Max Current 1A 2.5A
On/Off Switch None. Only power reset switch is provided Can attach an external on/off switch for manual on/off. Power reset by pulling shunt out/in
UPS USB Out Yes, via micro-USB Yes, via micro-USB OR via terminal blocks
GPIO used Yes None – internal ADC is used
Vin, Vout, Battery and temperature info None Available via an on-board 4 channel 12-bit ADC, accurate to 3mV (Temp =±2oC)
Pi-UpTime-UPS Pi-UpTime-UPS 2.0
Python code for shutdown Yes, depends on GPIO indicators Yes. Python code provides Vin, Vout, board temperature and Battery level. Can be modified for different use cases
External Battery None. Battery attached via the 18650-battery holder on board Battery attached via 18650 battery holder OR connected via terminal block. Terminal block is 2.54mm and is not included. Digikey part number ED10561-ND
Battery size One or two 18650 Li-Ion battery. Recommended capacity < 3500 mAh Can be any capacity. Higher capacity takes longer to charge & provides longer UPS run time
Battery Management CC-CV charging. Battery charge level maintained over time CC-CV charging. Battery charge level maintained over time
Safety CCCV charging, temperature monitoring CCCV charging, temperature monitoring, PTZ fuse to prevent battery loop current. System current limit of 2.5A
LED’s Many Green – Battery is charging

Blue – UPS is on

Yellow – Input V is below 4.8V

Red – Fault

Power in Via micro-USB Via USB-C or micro-USB or Terminal Blocks (not included)
UPS Power out Via micro USB Via micro USB or Terminal Blocks
Other Many units in use worldwide. Uses Ideal diode – very little heat or power loss – an efficient operation and seamless transition to battery backup for UPS
Shutdown Trigger point Hardware – cannot be modified Can be modified in software. Battery V level determines when shutdown is triggered and can be changed
Battery management / charging Built on board, uses CCCV charging Built on board, uses CCCV charging
Pi-UpTime-UPS Pi-UpTime-UPS 2.0
Board Color Green with white text Black with white text
Planned use / future Legacy. Not recommended for new designs Recommended for new designs
Other Provides 3.3V, 0.8A max UPS, protected by PTZ fuse Provides 3.3V, 0.8A max UPS, protected by PTZ fuse
I2C NA Onboard ADC uses I2C. I2C can be extended to external sensors via terminal block.
UPC code 691852747139 708088352584